If your Double door Referigerator is not working properly, then you have come to the right place. We have been offering top quality repair, installation, service. Our experience in this field has led us to thousands of satisfied customers all over Panchkula, Ziakpur, Chandigarh, Mohali, Peer Muchalla, Baltana, Dhakoli area. Our priority is to provide honest and satisfying solutions to our customers, for Referigerator repair. we provide an extraordinary repair service and maintenance in both areas.

No matter what type brand of refrigerator you have in your property, our team can get to work right away. From damaged parts to general service we are here to take care of the repair service and maintenance. BSD Enterprises is the premier service provider for refrigerator, ice maker repair of any brand.


Most Referigerator’s problems can be fixed the same day. you will still be able to save all the food that you have in the Referigerator. Be sure to call us: 9592913579 if you notice any of those. The Referigerator won’t turn on, is overcooling, is not cooling, makes awkward noise, leaks water, all the lights are off.

Refrigerator Parts We Replace:

  • Thermostats
  • Water filters
  • Replacement bulbs
  • Ice maker components
  • Defrost heaters
  • Cold controls
  • Door switches and seals
  • Condensers and compressors
  • Evaporators and fans


BSD engineers are all fully qualified, experienced and treat your property with the utmost care and attention. We guarantee that we will get your Double door Referigerator Repair Service work done right at first time.


We look forward to working on your problematic refrigerator.


For more information about our exceptional refrigerator repair service, contact us BSD Engineers our friendly customer support professionals at 9592913579.

BSD Satisfied customer
Customer Satisfaction Guarranteed

BSD Enterprises is serving @ 95% customer Satisfaction

BSD Skilled Engineers
LICENSED, INSURED AND CERTIFIED

Our Technicians are Certified, Licensed and insured for protection

BSD Excellent Relations
FIVE STANDARDS of EXCELLENCE

High Quality Service and Workmanship. We Back Everything by our five standards of excellence

BSD Proffesional Team Work
Operation & Maintenance Professionals
  • Professionally Trained
  • 100% Satisfaction Guaranteed
  • Work On All Brands
Tags...

Customer Reviews

FAQ - Refrigerator

Cooling in Freezer Only in Frost Free Fridge is due to improper fuctioning of defrost cycle in the refrigerator, which can be due to

  1. Faulty Bi-Metal Sensor
  2. Fauly Defrost heater
  3. Faulty Thermostat
  4. Faulty Temprature Sensor
  5. Faulty Programmed Control Circuit Board (PCB)
  6. Faulty Defrost Timer
  1. Main tip from our Team is, If any customer keeps on using faulty refrigerator, one fault leads to another fault, resulting in increase in cost of repairing,
    So, whenever there is less cooling in refrigerator, Shutdown the refrigerator and
    Please feel free to call us
  2. Keep the thermostat setting of the refrigerator according to the season and keep a check on it regularly

Single door fridge or Direct Cool Fridge starts overcooling when Thermostat is Faulty

Double door fridge or Frost Free Fridge starts overcooling Thermostat is Faulty

Single door Fridge/Direct Cool Fridge: Compressor stops wroking due to following reasons:

  1. Thermostat is faulty:Thermostat is used to control the cooling temperature of fridge (when temperature is high than desired set temperature, thermostat gives power supply to start the compressor.Now when temperature is achieved or temperature is as low as desired set temperature thermostat cuts off the power supply to the compressor & as soon as temperature rises above the desired set temperature, thermostat again starts the compressor). When internal electrical contact gets brunt out, or the sensor stops working it does not give power supply to start the compressor.
  2. Overload relay is faulty: Overload protection relay is used to protect the compressor against voltage fluctuation & overloading of compressor. Incase if there is high volatge fluctation & customer does not switch off the fridge, overload protection relay might get brunt out & it does not give supply to compressor.
  3. Compressor starting/running relay is faulty:Compressor start/run relay is used to give start to the compressor (Fridge compressor electric motor is a permanent capacitor start/run type motor. In this type of motor it is required to create a 90 degree phase shift of electric current between running winding & starting winding to run the motor & compressor start/run relay gives 90degree phase shift). If compressor start/run relay is faulty, compressoor stops working & of it is not replaced on time, compressor overload relay might also get brunt out.
  4. Compressor motor winding is brunt out: When compressor motor gets winding brunt out, motor stops working & compressor stops working.
  5. Compressor is stuck: Above mentioned all parts are electrical parts of compressor. Now as we come to the mechancial parts of compressor, compressor includes piston running in cylinder head, compressor sucks the low pressure liquid gas through suction/intake valve & compress the gas, & deliver high pressure gas through delivery valve. Now if piston gets stuck in the cylinder head, compressor stops working.
  6. Internal fridge wiring is brunt out. Wiring works as nerves to control and supply electric current to the compressor. If wiring gets brunt out, fridge gets malfunctioning & compressor stops working.
Double Door Fridge/Frost Free Fridge: In frost free fridge/double door fridge there is only one basic difference as the name itself explains that double door fridge gets defrost itself through control circuit. This control circuit includes: defrost timer, defrost heater, Bi-metal sensor or PCB. In double door fridge, compressor stops wroking due to following reasons:
  1. Defrost timer is faulty: Defrost timer is used to automatically def.rost the fridge
  2. Defrost heater is faulty bi-metal sensor
  3. Programmed Control Circuit Board(PCB) is faulty
  4. Thermostat is faulty:Thermostat is used to control the cooling temperature of fridge (when temperature is high than desired set temperature, thermostat gives power supply to start the compressor.Now when temperature is achieved or temperature is as low as desired set temperature thermostat cuts off the power supply to the compressor & as soon as temperature rises above the desired set temperature, thermostat again starts the compressor). When internal electrical contact gets brunt out, or the sensor stops working it does not give power supply to start the compressor.
  5. Overload relay is faulty: Overload protection relay is used to protect the compressor against voltage fluctuation & overloading of compressor. Incase if there is high volatge fluctation & customer does not switch off the fridge, overload protection relay might get brunt out & it does not give supply to compressor.
  6. Compressor starting/running relay is faulty:Compressor start/run relay is used to give start to the compressor (Fridge compressor electric motor is a permanent capacitor start/run type motor. In this type of motor it is required to create a 90 degree phase shift of electric current between running winding & starting winding to run the motor & compressor start/run relay gives 90degree phase shift). If compressor start/run relay is faulty, compressoor stops working & of it is not replaced on time, compressor overload relay might also get brunt out.
  7. Compressor motor winding is brunt out: When compressor motor gets winding brunt out, motor stops working & compressor stops working.
  8. Compressor is stuck: Above mentioned all parts are electrical parts of compressor. Now as we come to the mechancial parts of compressor, compressor includes piston running in cylinder head, compressor sucks the low pressure liquid gas through suction/intake valve & compress the gas, & deliver high pressure gas through delivery valve. Now if piston gets stuck in the cylinder head, compressor stops working.
  9. Internal fridge wiring is brunt out. Wiring works as nerves to control and supply electric current to the compressor. If wiring gets brunt out, fridge gets malfunctioning & compressor stops working.
Fridge/Refrigerator stops cooling due to following reasons:
  1. Compressor is Faulty
  2. Refrigerant/Gas Leakage
  3. Refrigerant/Gas choking
  4. Faulty Elecrical Control Equipment i.e.defrost timer, defrost heater, Bi-metal sensor or PCB etc.
Fridge/Refrigerator stops cooling due to following reasons:
  1. Compressor is Faulty
  2. Refrigerant/Gas Leakage
  3. Refrigerant/Gas choking
First of all, if there is huge amount of ice deposited in the freezer, please defrost the freezer through thermostat or just switch off the refrigerator till the ice is fully melt.
Now if there is hole in the freezer, first of all switch off the refrigerator at once and call us, our techicians:
  1. Check the compressor for its proper functioning and ensures if there is any water in the suction line of Compressor
  2. If there is water in compressor, compressor has to be replced
  3. And if there is no water in the compressor, freezer is replaced along with filter, capillary tube and suction pipe
  4. Then leakage testing is done to ensure there is no leakage in the system
  5. Then Technician vaccuumm the system fully
  6. Refrigerant/Gas is Charged to the proper level
If there is water leakage in the refrigerator, drain has to cleaned of the freezer compartment and if there is any faulty part/setting due to which the drain was choked, faulty parts can be: defrost timer, defrost heater, Bi-metal sensor or PCB etc.

FAQ BSD ENTERPRISES

There is 3 months warranty on the workmanship of the technician and minimum 3 months warranty on spare part or
warranty specified by company on that spare part (for ex. 1 year warranty on compressor) and
sometimes no warranty if spare part made of plastic or Company is not offering any warranty

Labour cost depends on the type/amount of Work to be done to repair the faulty machine
and Visit charges only include the checking of machine to find the fault and give an estimate

We give free estimates on call only, if visiting the customer premises is required to give an estimate, our Trained techincians visits the said premises, gives an estimate and If customer gives a positive consent to the technician, he gets the work done and charge the money according to the estimate given and if customer just wanted to get the estimate, our technician charges only visit charges or checking charges.

BSD Enterprises do not have any spare parts with them
If there is any requirement of any spare part, our Technicians visit the particular authorised spare part dealer of the company of which part is required

Whenever Customer calls us for any type of repair service required, our Trained Technician visits the customer and identify the fault, gives an estimate to the customer
If customer gives a positive consent to the technician, he repairs the fault and charge the money according to the estimate given,
And no extra Visit charges are taken by us

Yes BSD Engineers calls the customer before reaching at their doorstep

Yes we provide week-end service

BSD Enterprises do not sell any spare parts
If there is any requirement of any spare part, our Technicians visit the particular authorised spare part dealer of the company of which part is required

BSD Enterprises

Serving the whole Tri- city with the best Technicians with Latest Tools, we have gained a great experience in understanding the demands of the customer and delivering them with the best services.

We are famous for our quality services with competitive price with time commitment. Our highly qualified, trained, professional technical team is our main strength. Our experts do repair & Service for all brands.We service both residential and commercial accounts.

For any other query call us at 9592913579.

We provide services in: