BSD Enterprises is serving @ 95% customer Satisfaction
LICENSED, INSURED AND CERTIFIED
Our Technicians are Certified, Licensed and insured for protection
FIVE STANDARDS of EXCELLENCE
High Quality Service and Workmanship. We Back Everything by our five standards of excellence
Operation & Maintenance Professionals
Professionally Trained
100% Satisfaction Guaranteed
Work On All Brands
Window AC Service
Trouble with your AC ?
We are Providing All types of AC Service.We have more than 7 years of experience in the air Conditioner Service in Panchkula.
Air conditioner is one the most important in Summers. INDIA can get really hot. you stay cool and comfortable in the hot summers.
BSD engineers are all fully qualified and experienced. Air-conditioner now not switching On, low cooling, low air blowing and all specific minor and maximum essential problems of Air-conditioner. BSD Engineers providing to best service.We have certified AC technicians.
You are problems with your window air conditioner. Now no need to worry while having an issue with your Air Conditioner working, BSD enterprises finds the solut+ion of all AC relaeted problem. BSD Enterprises functionality to provide service and restore your Air-conditioner.
We provide All Brands AC service. Our experts provide the most best services without any fuss and that too at a very legitimate and reasonable price.Full customer satisfaction and quality service.
All you need to do is to fill the booking form on our website or call on our customer helpline number 9592913579
Customer Satisfaction Guarranteed
BSD Enterprises is serving @ 95% customer Satisfaction
LICENSED, INSURED AND CERTIFIED
Our Technicians are Certified, Licensed and insured for protection
FIVE STANDARDS of EXCELLENCE
High Quality Service and Workmanship. We Back Everything by our five standards of excellence
AC should be serviced at least once a year during the start of summers.
It depends upon following requirements,
Operating time of AC: In India we have all kind of persons living near us, some keeps their AC ‘ON’ for whole day, and some operate only during night, and some for two hours before going to sleep.
So, the funda is simple as long the operating time of AC more frequently is the requirement of service.
Surrounding conditions: There are different surrounding conditions according to the situation of the building i.e.,
Park facing
Main road near them
Commercial Building in market
Commercial building in Motor Market
Society near highway
House near farm
House in Sector
Near a under construction building
Different surroundings, different amount of dust, dirt, pollution etc., More is the value of dust, dirt and pollution, more is the requirement of service of AC.
AC or “air conditioner” works on the principle of compression of refrigerant gas. It has many different parts assembled together to create cooling effect. Main parts are:
Compressor
Condenser Coil
Expansion Valve (Capillary Tube)
Evaporator Coil
Condenser fan Motor with fan Blade
Evaporator Blower Motor with blower
PCB (Control Circuit)
If any of the above part becomes faulty, AC stops working and,
with cleaning of these parts smooth working of AC is insured.
If we do not get our AC service regularly, it leads to failure of AC through following steps,
Compressor starts working extra to compensate the heat loss due to dirty condenser coil.
Compressor starts overheating.
During which starting and running capacitor might get burnt, and
Compressor pumps oil with refrigerant.
Oil gets stuck in part Capillary Tube, in this case Capillary Tube should be replaced with oil and gas.
Now if Capillary Tube is not replaced, it results in full choking of gas, which leads to further overloading of compressor.
In that event, even compressor might get burnt out. In this case compressor has to be replaced.
There are many possibilities that can cause AC system to freeze up:
Dirty filter: Dirty Filter results in low air flow, which further results in freezing up of Evaporator coil
Low refrigerant: Whenever there is low refrigerant value in AC, it results in low discharge pressure/temprature and suction pressure, which further results in freezing up of AC.
Dirty evaporator coil: When evaporator coil will become dirty, there is low airflow and it freezes up.
Defective blower motor or relay: A blower motor running at low speed, sometimes not running at all causes freezing.
Whenever the pressure/ volume of refrigerant gas is low then the required pressure/ volume, gas charging is required.
Here main thing to note is how gas pressure / volume get low:
Leakage: Leakage of gas can be due to several reasons, i.e.,
Loose flaring nut joints: Split AC, sometimes flaring nut joint get loose due to overheating of compressor/ outdoor unit due to following reasons,
When outdoor unit is placed under direct sun
When AC is used above its capacity, i.e., when AC is running regularly for long hours, when area is too big for AC to attain/maintain desired temperature
Leak Brazing joints: Brazing is done at several points in outdoor and indoor unit, and when copper pipe is required to be joined, gas is leaked if at any point brazing is not done properly
Puncture of Copper pipe
Puncture of condenser coil/ evaporator coil.
Choking of Gas: When Compressor starts overheating.
Compressor pumps oil with refrigerant.
Oil gets stuck in part Capillary Tube, resulting in choking of gas.
Compressor Replacement: When ever compressor is replaced, Refrigerant gas charging is required.
Increase in Length of copper pipe connecting indoor unit and outdoor unit
Electricity bill can be reduced by following ways:
Installation of proper capacity of AC with respect to heat load of area.
Heat Load calculation can be done by a professional through measurement of room but when choosing for home there is no requirement of such professionals. There is simple funda:
1 ton AC = 10*10*10 feet room
1.5 ton AC= 15*15*10 feet room
2.0 ton AC=20*20*10 feet room
Operate AC at 22°C to 25°C
Many of users think that, operating the AC at 18°C would cool the room fast as compared to 22°C setting, which is completely wrong.
It doesn’t make any difference if you operate your AC at any temp. On the amount of cooling that your AC provide at a time. Only difference that it makes is,
if user set the desired temp at 22°C, the compressor would stop at 21°C at again restart at 23°C
and if user set the desired temp. at 18°C, the compressor would stop at 17°C at again restart at 19°C.
So if user operates the AC at 22°C to 25°C the compressor would stop early as compared to 18°C, which helps in reducing the electricity bill.
Compressor of AC stops working due to following reasons:
Compressor is fully damaged
Compressor motor winding is brunt out
Compressor piston is stuck
Due to electrical faults
Thimble brunt out
Connecting Wire Break
Faulty Starting Relay
Faulty Starting Capacitor
Faulty running Capacitor
Faulty Programmed Control Circuit Board (PCB)
Main tip from our Team is, If any customer keeps on using faulty AC, one fault leads to another fault, resulting in increase in cost of repairing, So, whenever there is less cooling in AC, Shutdown the AC and Please feel free to call us
Water Leakage in AC can be due to following reasons:
Dirty Indoor Unit
Dirty Drain Tray
Dirty Back Drain tray
Choked Drain Pipe
Improper Installation of AC
Proper cleaning of indoor AC-unit means
Cleaning of Dust Filters
Cleaning Of Evaporator Coil, From Front as well as From Back
Cleaning of Front drain Tray and back drain tray
Cleaning of PCB Section
Cleaning of Blower
Cleaning of Whole plastic body
Checking of Copper Pipe Insulation behind Indoor Unit
Cleaning of Flexible Drain Pipe attached with Indoor unit
FAQ BSD ENTERPRISES
There is 3 months warranty on the workmanship of the technician and minimum 3 months warranty on spare part or warranty specified by company on that spare part (for ex. 1 year warranty on compressor) and sometimes no warranty if spare part made of plastic or Company is not offering any warranty
Labour cost depends on the type/amount of Work to be done to repair the faulty machine and Visit charges only include the checking of machine to find the fault and give an estimate
We give free estimates on call only, if visiting the customer premises is required to give an estimate, our Trained techincians visits the said premises, gives an estimate and If customer gives a positive consent to the technician, he gets the work done and charge the money according to the estimate given and if customer just wanted to get the estimate, our technician charges only visit charges or checking charges.
BSD Enterprises do not have any spare parts with them If there is any requirement of any spare part, our Technicians visit the particular authorised spare part dealer of the company of which part is required
Whenever Customer calls us for any type of repair service required, our Trained Technician visits the customer and identify the fault, gives an estimate to the customer If customer gives a positive consent to the technician, he repairs the fault and charge the money according to the estimate given, And no extra Visit charges are taken by us
Yes BSD Engineers calls the customer before reaching at their doorstep
Yes we provide week-end service
BSD Enterprises do not sell any spare parts If there is any requirement of any spare part, our Technicians visit the particular authorised spare part dealer of the company of which part is required
BSD Enterprises
Serving the whole Tri- city with the best Technicians with Latest Tools, we have gained a great experience in understanding the demands of the customer and delivering them with the best services.
We are famous for our quality services with competitive price with time commitment. Our highly qualified, trained, professional technical team is our main strength. Our experts do repair & Service for all brands.We service both residential and commercial accounts.